causes of aeration and cavitation are a collapsed, restricted or poorly designed inlet; clogged or improperly sized reservoir breathers; loose clamps or fittings, porous intake lines, or a low reservoir oil level. Repair or replace all suspect components and ensure that the reservoir is properly filled.
Problem
The fluid has small particles in it.
Fixes: Particulate contamination may be one of the most common problems with skid-steer hydraulic systems because they are always exposed to dirty environments. This, coupled with hurried or careless connections and disconnections, can easily cause contamination. Whereas the filtration system is designed to remove most of the particulates, sometimes the contamination exceeds the filter’ s ability to filter. This too may necessitate a clean flush. So, it is necessary to be vigilant when it comes to cleaning. Ultimately, prevention is the best kind of maintenance.
Maintenance: Whenever disconnecting a fluid line, wipe the couplers down with a clean rag first. And after making a reconnection or close-coupling the system for the day, wipe it down again. Try keeping couplings from being exposed to dust and wind as much as possible when not being used.
A Word About Attachments
Another reason that the skid steer is so popular is its versatility. The machine itself comes in three general sizes: large frame, medium frame and small frame( also known as a mini). A skid loader also may have more available accessories than Barbie and Ken( there are literally dozens)! In addition to hauling heavy loads, a skid steer can be used as a brush cutter, a trencher, a grapple or a forklift, depending on the attachment that is used. Do you need to install long runs of fencing? With an auger
September 2024 • www. thepartsconnection. org • 17